Validation and clinical application of a method to quantify efavirenz in cervicovaginal secretions from flocked swabs using liquid chromatography tandem mass spectrometry

No Thumbnail Available

Date

2022-07-08

Authors

Olagunju, Adeniyi
Nwogu, Jacinta
Eniayewu, Oluwasegun
Atoyebi, Shakir
Amara, Alieu
Kpamor, John
Bolaji, Oluseye
Adejuyigbe, Ebunoluwa
Owen, Andrew
Khoo, Saye

Journal Title

Journal ISSN

Volume Title

Publisher

Wellcome Open Research

Abstract

Background : A liquid chromatography tandem mass spectrometry method to quantify drugs in dried cervicovaginal secretions from flocked swabs was developed and validated using the antiretroviral efavirenz as an example. Methods: Cervicovaginal swabs (CVS) were prepared by submerging flocked swabs in efavirenz-spiked plasma matrix. Time to full saturation, weight uniformity, recovery and room temperature stability were evaluated. Chromatographic separation was on a reverse-phase C18 column by gradient elution using 1mM ammonium acetate in water/acetonitrile at 400 µL/min. Detection and quantification were on a TSQ Quantum Access triple quadrupole mass spectrometer operated in negative ionisation mode. The method was used to quantify efavirenz in CVS samples from human immunodeficiency virus (HIV)-positive women in the VADICT study (NCT03284645). A total of 98 samples (35 paired intensive CVS and DBS pharmacokinetic samples, 14 paired sparse CVS and DBS samples) from 19 participants were available for this analysis. Results: Swabs were fully saturated within 15 seconds, absorbing 128 µL of plasma matrix with coefficient of variation (%CV) below 1.3%. The method was linear with a weighting factor (1/X) in the range of 25-10000 ng/mL with inter- and intra-day precision (% CV) of 7.69-14.9%, and accuracy (% bias) of 99.1-105.3%. Mean recovery of efavirenz from CVS was 83.8% (%CV, 11.2) with no significant matrix effect. Efavirenz remained stable in swabs for at least 35 days after drying and storage at room temperature. Median (range) CVS efavirenz AUC 0-24h was 16370 ng*h/mL (5803-22088), C max was 1618 ng/mL (610-2438) at a T max of 8.0 h (8.0-12), and C min was 399 ng/mL (110-981). Efavirenz CVS:plasma AUC 0-24h ratio was 0.41 (0.20-0.59). Conclusions: Further application of this method will improve our understanding of the pharmacology of other therapeutics in the female genital tract, including in low- and middle-income countries.

Description

Keywords

LC-MS/MS, Cervicovaginal fluid, Swab, Pharmacokinetics, Efavirenz

Citation

Collections