Detection and Classification of Stator Short-Circuit Faults in Three-Phase Induction Motor

dc.contributor.authorAbdullateef, A. I
dc.contributor.authorFagbolagun, O.S
dc.contributor.authorSanusi, M. F
dc.contributor.authorAkorede, M.F
dc.contributor.authorAfolayan, M.A
dc.date.accessioned2021-06-03T13:47:22Z
dc.date.available2021-06-03T13:47:22Z
dc.date.issued2020
dc.description.abstractInduction motors are the backbone of the industries because they are easy to operate, rugged, economical and reliable. However, they are subjected to stator’s faults which damage the windings and consequently lead to machine failure and loss of revenue. Early detection and classification of these faults are important for the effective operation of induction motors. Stators faults detection and classification based on wavelet Transform was carried out in this study. The feature extraction of the acquired data was achieved using lifting decomposition and reconstruction scheme while Euclidean distance of the Wavelet energy was used to classify the faults. The Wavelet energies increased for all three conditions monitored, normal condition, inter-turn fault and phase-to-phase fault, as the frequency band of the signal decreases from D1 to A3. The deviations in the Euclidean Distance of the current of the Wavelet energy obtained for the phase-to-phase faults are 99.1909, 99.8239 and 87.9750 for phases A and B, A and C, B and C respectively. While that of the inter-turn faults in phases A, B and C are 77.5572, 61.6389 and 62.5581 respectively. Based on the Euclidean distances of the faults, Df and normal current signals, three classification points were set: K1 = 0.60 x 102, K2 = 0.80 x 102 and K3 = 1.00 x 102. For K2 ≥ Df ≥ K1 inter-turn faults is identified and for K3 ≥ Df ≥ K2 phase to phase fault identified. This will improve the induction motors stator’s fault diagnosis.en_US
dc.identifier.citationAbdullateef, A. I., Fagbolagun, O. S., Sanusi, M. F., Akorede, M. F., & Afolayan, M. A. (2020): Detection and Classification of Stator Short-Circuit Faults in Three-Phase Induction Motor. Journal of Applied Science & Environmental Management, 24(3), 417–424, Published by University of Port Harcourt. Available online at https://www.ajol.info/index.php/jasemen_US
dc.identifier.urihttps://uilspace.unilorin.edu.ng/handle/20.500.12484/5876
dc.publisherJournal of Applied Science & Environmental Managementen_US
dc.subjectinduction motoren_US
dc.subjectstator fault classificationen_US
dc.subjectdata acquisition systemen_US
dc.subjectDiscrete Wavelet Transformen_US
dc.titleDetection and Classification of Stator Short-Circuit Faults in Three-Phase Induction Motoren_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Detection and Classification of Stator Short-Circuit Faults in Three-Phase Induction.pdf
Size:
394.37 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.69 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections