Effect of Draught on Evaporative Cooling in Earthenware Ports
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
JSET
DOI
Abstract
An earthenware pot filled with water was exposed to draughts of 8.9 km/h and 15.7 km/h, at different times, from a fan. Water temperature, room air dry-bulb temperature and relative humidity and mass of water left in the pot were measured hourly or bi-hourly. Water temperature depressions up to 106 % of wet bulb depression and water cooling rates up to 146 W per square metre surface area of the pot were obtained.
Description
Keywords
Citation
Olorunmaiye, J. A. (1996). Effect of Draught on Evaporative Cooling in Earthenware Ports. Journal of Science Engineering and Technology, 3(2), 460–470.