Effect of Draught on Evaporative Cooling in Earthenware Ports

No Thumbnail Available

Date

1996-10

Journal Title

Journal ISSN

Volume Title

Publisher

JSET

Abstract

An earthenware pot filled with water was exposed to draughts of 8.9 km/h and 15.7 km/h, at different times, from a fan. Water temperature, room air dry-bulb temperature and relative humidity and mass of water left in the pot were measured hourly or bi-hourly. Water temperature depressions up to 106 % of wet bulb depression and water cooling rates up to 146 W per square metre surface area of the pot were obtained.

Description

Keywords

Evaporative cooling, Earthen pots, Effect of draught

Citation

Olorunmaiye, J. A. (1996). Effect of Draught on Evaporative Cooling in Earthenware Ports. Journal of Science Engineering and Technology, 3(2), 460–470.