Browsing by Author "Usman, A.O."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Characterizing gully‑prone zones using geophysical and geotechnical approaches: a case study of Njaba South‑Eastern Nigeria(SPRINGER, 2023-11-14) Akakuru, O.C.; Opara, A.I.; G. O. Aigbadon, G.O.; Usman, A.O.; Ibeneme, S.I.; Iheme, K.O.; Njoku, A.O.; Akudinobi, B.E.B.Over the years, Njaba has been known to be bedeviled with worrying gully erosion challenges. This is attributed to the geologic makeup of the soil and other environmental factors. Geophysical and geotechnical characterization of the soil within Njaba and its environs has been carried out with the aim of determining the potentials in the development and enhancement of gullies within the area. 23 vertical electrical sounding were conducted using Schlumberger array configuration with maximum current electrode spacing of 350 m, while two soil samples were also collected for geotechnical studies. The first layers were used to categorize the soils into competence and corrosive soils. Qualitative interpretation reveals that the sites are characterized by six (6) resistivity type curves, namely; 6-HK, 2-AK, 3-KH, 2-QH, 4-KK, 2-AH. The results from the iso-resistivity showed that the resistivities of the layers increased progressively with depth as the maximum electrode spacing increased. The transverse resistance calculated varies from 1408950 to 30987 Ωm, and the longitudinal conductance varies from 0.03163 to 0.00099876 mho. From the competence and corrosivity rating, the soils were categorized from highly competent to moderately competent for the competence categories with varying resistivities of 2800 to 154 Ωm and for the corrosivity category, soils were categorized from essentially non-corrosive to mildly corrosive soils with varying resistance of 182.0 to 154.0 Ωm. The coefficient of anisotropy determined averages 1.25, 1.14 and 1.06 at three different sites. The results of the compaction tests indicate that the Optimum Moisture Content ranged from 11.1–11.5% is required to achieve Maximum Dry Density of the samples ranging from 0.18–2.15 mg/m3. From the study, it can be ascertained that the soil is of low compressibility. The study suggests among others that surface and subsurface flows and drainage should be controlled by directing water through concrete channels into lined artificial reservoirs or straight into lakes or river plains.Item Hydrogeochemical evolution, water quality indices, irrigation suitability and pollution index of groundwater (PIG) around eastern Niger Delta, Nigeria(Published by International Journal of Energy and Water Resources., 2022) Akakuru, O. C.; Eze, C.U.; Okeke, O. C.; Opara, A.I.; Usman, A.O.; Iheme, K.O.; Ibeneme, S.I.; Iwuoha, P.O.The study was done to assess groundwater for different uses. Groundwater samples were collected from 17 locations and analyzed for physicochemical attributes. Hydrogeochemical data identified three significant Principal Components; PC1, 53.8% loadings, PC2, 46.2% loadings, PC3, 30.8% positive loadings. Correlation matrix analysis observed strong correlations in the majority of the parameters. Contamination Factor results reveal that HCO3, NO3, Na, Ca, and Mg had relatively low concentration < 1; Fe had a mean concentration of 1.18 (moderate contamination), while SO4, and Cl, had mean concentrations of 6.43 and 9.41, respectively. PLI result reveals that the samples had values less than 1. WQI result revealed that 11.7% of the samples are excellent, 82.4% of the water is of good quality, 5.9% are of poor quality. PIG result shows insignificant pollution of groundwater. The hydrogeochemical evolution shows Ca + Mg and Cl are the dominant ionic species in the cation and anion areas, respectively; and they are within the geochemical zone of 6 (calcium chloride water type) with a trend of Cl > SO4 > Ca > Mg > HCO3 > Na + K. From the Gibbs plot, rock-dominance zone is dominant in the groundwater samples. The suitability for irrigation analysis reveals that SAR, %NA, KR, and SSP in the entire study area are 100% suitable and fit for irrigation purposes, while MH had 88.2% of the sample as good and 11.8% as unsafe. The Wilcox plot shows that 70.6% of the entire sample belong to the excellent category whereas, 29.4% are of good to permissible category. Normal observing Normal observing of groundwater in the review region is of major significance.