Performance Evaluation of Aluminum-in-Pot Evaporative Cooler

dc.contributor.authorOlalekan Tajudeen POPOOLA
dc.contributor.authorIssa, Haruna Ayotunde
dc.contributor.authorAdegun, Isaac Kayode
dc.contributor.authorOmoniyi, Peter Olorunleke
dc.contributor.authorIbrahim, Hassan Kobe
dc.date.accessioned2026-05-11T10:53:49Z
dc.date.available2026-05-11T10:53:49Z
dc.date.issued2025
dc.description.abstractCooling applications by refrigeration and air-conditioning require electricity as a source of energy not abundantly available in sub-Saharan African countries. Post-harvest losses of vegetables are caused by poor storage facilities, poor transportation systems, and lack of processing facilities. The current study aimed to evaluate the performance of developed solar-powered Aluminium-in-pot evaporative coolers lined with clay and charcoal blends for the preservation of tomatoes. The evaporative cooler consisted of Aluminium pots inserted into an earthenware mould pot, and the space between the two pots filled with lining media of clay, charcoal, and blends of the two in different ratios. The dry bulb temperature of the ambient air, inner temperatures of the cooling chambers, and relative Humidity were measured using fresh tomatoes as a load for the coolers. The temperature variations of the coolers were recorded for fifteen consecutive days. It was found that the inner temperatures for the five evaporative coolers were significantly different from the dry bulb temperature of the ambient. The temperature of sample E had the lowest temperature range of 19.65 C to 23.65 C for the no-load test, 21.15 C to 25.29 C for the load–load-test (better boy), and 21.1 to 23.25 C for the load test (Plum). The daily temperature in the coolers dropped significantly to a range of between 3.4 C to 10.46 C with a corresponding daily RH range of 30.93% to 39%. The variations in the efficiency of Sample E were found to be averagely 84% at no load, 72% when loaded with Better Boy and 77% when loaded with Plum tomatoes. The aluminium in pot evaporative cooler could be used for a short-term preservation of tomatoes in remote areas where electricity is not available.
dc.identifier.otherhttps://doi.org/10.18011/bioeng.2025.v19.1319
dc.identifier.urihttps://uilspace.unilorin.edu.ng/handle/123456789/18303
dc.language.isoen
dc.publisherSchool of Science and Engineering, São Paulo State University (UNESP)
dc.relation.ispartofseries19
dc.subjectAluminium-in-pot
dc.subjectEvaporative cooling
dc.subjectLining
dc.subjectSaturation Efficiency
dc.subjectThermodynamics
dc.titlePerformance Evaluation of Aluminum-in-Pot Evaporative Cooler
dc.typeArticle

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
View of Performance evaluation of aluminum-in-pot evaporative cooler.pdf
Size:
4.09 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections