Test systems for the biomechanical evaluation of hip protectors: a systematic review

dc.contributor.authorYahaya, S. A.
dc.contributor.authorRipin, Z.
dc.contributor.authorRidzwan, M.
dc.date.accessioned2020-02-19T10:15:55Z
dc.date.available2020-02-19T10:15:55Z
dc.date.issued2019
dc.description.abstractVarious mechanical and biomechanical test systems to evaluate the effectiveness of hip protectors designed to prevent hip fracture as a result of falls were examined in this review. The articles considered were selected systematically. The effect of differences in design criteria was demonstrated, and it was observed that the impact energy employed during testing dramatically affects the performance of the hip protector. Over the past three decades, researchers have continuously experimented with various systems to determine the efficacy of various hip protectors. The primary aim has been to make informed decisions in optimizing hip protector design. This article provides a systematic review of various test systems employed in the determination of the biome- chanical efficacy of hip protectors. A systematic literature search was carried out, and 28 relevant articles were included to demonstrate the effect of test systems in the evaluation of the biomechanical effectiveness of hip protectors. Methodological studies illustrated the appropriate use of impact testing systems for the simulation of hip anatomy and fall dynamics in evaluating the effectiveness of hip protectors in preventing a hip fracture. This systematic review has demonstrated the effect of the variability of test systems on the evaluation of impact attenuation by various hip protectors. The lack of standardized test systems accounts for the inconsistencies in the test results of the efficacy of hip protectors. This has been a major challenge in the efforts of researchers to optimize the interventions. The standardization of test systems may require needed improvements immediately as opposed to the development of new interventions in order to ensure that only hip protectors with adequately proven efficacies are deployed for clinical trials or for the protection of the hips of vulnerable individuals from sideways impact.en_US
dc.description.sponsorshipUSM grant 1001/PMEKANIK/8014070.en_US
dc.identifier.citationYahaya, S. A, Ripin, Z. & Ridzwan, M. (2019), Test systems for the biomechanical evaluation of hip protectors: a systematic review. Osteoporos Int https://doi.org/10.1007/s00198-019-05128-xen_US
dc.identifier.urihttp://hdl.handle.net/123456789/3721
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.subjectBiomechanical effectivenessen_US
dc.subjectFractureen_US
dc.subjectHip protectoren_US
dc.subjectHip paden_US
dc.subjectMechanical testingen_US
dc.subjectOsteoporotic hipen_US
dc.titleTest systems for the biomechanical evaluation of hip protectors: a systematic reviewen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Yahaya_et_al-2019-Osteoporosis_International.pdf
Size:
755.92 KB
Format:
Adobe Portable Document Format
Description:
Main article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.69 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections